Components
1.BAM-conjugated detection mAb (7-B6-1).
2.Biotinylated detection mAb(MT28).
3.WASP-conjugated detection mAb (MT20D9).
4.Anti-BAM-490.
5.SA-550.
6.Anti-WASP-640anti-CD3 mAb.
7.Anti-CD28 mAb(CD28-A).
8.Fluorescence enhancer.
9.2 Pre-coated FluoroSpot plates (mAbs 1-D1K,MT34B6,MT25C5).
Assay Procedure
1.Remove the plate from the sealed package and wash the plate three times with sterile PBS (200 μl/well).
2.Block/ condition the plate by adding cell incubation medium containing 10% fetal calf serum (200 ul/well). Incubate for at least 30 minutes at room temperature.
3.Remove the medium and add the stimuli followed by the cell suspension. Cells and stimuli can also be mixed before addition to the plate.
4.Incubate the cells in the plate at 37°C in a humidified incubator with 5% CO2.
5.Remove the cells by emptying the plate and then wash the plate five times with PBS (200ul/well).
6.Dilute the detection antibodies in PBS containing 0.1 % BSA (PBS-0.1% BSA) according to the table above. If more than one analyte is analyzed, dilute the detection antibodies in the same tube. Add 100 μl/well and incubate for 2 hours at room temperature.
7.Wash the plate five times with PBS (200 ul/well).
8.Dilute the fluorophore-conjugates in PBS-0.1 % BSA to the concentrations as shown in the table above. If more than one analyte is analyzed, dilute the conjugates in the same tube. Add 100 μl/well and incubate for 1 hour at room temperature. Protect the plate from light throughout the assay.
9.Wash the plate five times with PBS (200 ul/well).
10.Empty the plate, add Fluorescence enhancer (50 ul/well), and leave for 5-15minutes at room temperature.
11.Empty by flicking the plate to remove the Fluorescence enhancer.
12.Remove the underdrain (the soft plastic drain under the plate).Dry the plate protected from light. The plate should be completely dry before analysis.Store plate in the dark at room temperature.
13.Spot analysis is performed with an automated FluoroSpot reader equipped with filters for the fluorophores used. Filters should have high specificity to avoid bleed-through artifacts.
Format
BAM-conjugated detection mAb (7-B6-1),Biotinylated detection mAb (GB11),WASP-conjugated detection mAb (MT20D9),Anti-BAM-490,SA-550,Anti-WASP-640,anti-CD3 mAb,Anti-CD28 mAb (CD28-A),Fluorescence enhancer,Pre-coated FluoroSpot plates (mAbs 1-D1K, GB10, MT25C5)
Precaution of Use
We recommend the use of PVDF-based membrane plates. Maximal antibody binding capacity of these platesis obtained by a brief treatment with ethanol.
Handling Advice
PBS for washing and dilution should be filtered (0.3 um) for optimal results.Although possible to use, we donot recommend the inclusion of Tween or other detergents in the washing and incubation buffers.
Storage Comment
Plates should be kept at room temperature.
Expiry Date
The expiry date indicates how long unopened products, stored according to instructions, are recommended for use.
Note
Serum should be selected to support cell culture and give low background staining. We recommend the use of fetal calf serum. Alternatively, serum-free medium evaluated for cell culture can be used.
Restrictions
For Research Use Only. Not for use in diagnostic procedures.