Close

Human Magnetic Luminex Mutiplex key Cytokine Array Kit-17 Plex (CAR-K-LX-013)

Online Inquiry  Datasheet

All products and services are For Research Use Only and CANNOT be used in the treatment or diagnosis of disease.

Specific Inquiry

  • Size:
  Add to Cart
  • Product Name
  • Human Magnetic Luminex Mutiplex key Cytokine Array Kit-17 Plex
  • Cat. No.
  • CAR-K-LX-013
  • Product Summary
  • A membrane-based antibody array for the parallel determination of the relative levels of selected human cytokines and chemokines. Validated for analyte detection in cell culture supernates, cell lysates, tissue lysates, serum, and plasma.
  • Components
  • 10X Human Key Cytokines Capture Particles: 1 x 1.65ml;
    10X Wash Buffer: 1 x 25ml;
    15X Human Key Cytokines Biotin Detectors: 1 x 367µl;
    2X Human & NHP Assay Diluent: 1 x 15ml;
    5X Reporter Solution: 1 x 4ml;
    96-well microplate with a filter: 1 unit;
    Filter Plate Seal: 1 x 3 units;
    Human Multiplex Immunoassay Protein Standard Mix A: 1 vial;
    Tungsten cleaning wire: 1 unit;
  • Precision
  • Intra-assay: <15
    Inter-assay: <15
  • Applications
  • Simultaneously analyze multiple cytokine and chemokine and other biomarkers with Bead-Based Multiplex Assays using the Luminex technology.
  • Product format/Physical form
  • 96-well microplate
  • Assay Type
  • Multiplex
  • Cross-reactivity
  • No significant cross-reactivity was observed among analytes in this panel.
  • Species Reactivity
  • Human
  • Sample Type (General)
  • Cell culture supernatant, Saliva, Milk, Urine, Serum, Cell culture extracts, Other biological fluids, Hep Plasma, EDTA Plasma, Cit plasma, Tissue Homogenate, Cerebral Spinal Fluid.
  • Shipping Condition
  • The product is recommended to be shipped on dry ice.Upon receipt, store immediately at recommended temperature below.
  • Storage Conditions
  • Store the unopened kit at 2 °C to 8 °C. Do not use past kit expiration date.
  • Plex size
  • 17
  • Dtection Coverage
  • GM-CSF, IFN gamma, IL-1 beta, IL-2 , IL-4, IL-5, IL-6, IL-8, IL-9, IL-10, IL-12p70, IL-13, IL-17A, MCP1, MIP1a, MIP1b,TNF alpha
  • Performance Validation
  • Our Luminex Assays undergo our most extensive validation testing. All Luminex Assays are validated for use with serum and plasma samples and tested for sensitivity (three-quarters the low standard), intra-assay precision, inter-assay precision, and to ensure assay linearity for validated sample types.
  • Detection method
  • Fluorescent
  • Product Features
  • Availability: able to detect analytes across a large-scale of concentrations reliably.
    High throughput multiplex analysis.
    Efficiency in terms of time and cost for multiple targets.
  • Principle of the Assay
  • To identify specific cytokines involved in any inflammatory or immune response, it might be necessary to screen panels of cytokines, often requiring some level of automation and/or high throughput. Magnetic Beads can make the process of automation and high throughput screening easier with features such as walk-away washing.
  • Research Category
  • Inflammation & Immunology
  • Application Notes
  • This kit may be used for the analysis of all or any combination of the cytokines and chemokines in serum, plasma or tissue/cell lysate and culture supernatant samples.
  • Accuracy
  • >80%
  • Panel Type
  • MAGNETIC Cytokines/Chemokines/Other Markers

Customer Reviews and Q&As

There are currently no customer reviews or questions for Human Magnetic Luminex Mutiplex key Cytokine Array Kit-17 Plex (CAR-K-LX-013). Click the button below to contact us or submit your feedback about this product.

For research use only. Not intended for any clinical use. No products from Creative Biolabs may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative Biolabs.

Related Products

Online Inquiry

For any technical issues or product/service related questions, please leave your information below. Our team will contact you soon.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Key Updates
Newsletter NEWSLETTER

The latest newsletter to introduce the latest breaking information, our site updates, field and other scientific news, important events, and insights from industry leaders

LEARN MORE NEWSLETTER
New Solution NEW SOLUTION

CellRapeutics™ In Vivo Cell Engineering: One-stop in vivo T/B/NK cell and macrophage engineering services covering vectors construction to function verification.

LEARN MORE SOLUTION
NOVEL SOLUTION NOVEL TECHNOLOGY

Silence™ CAR-T Cell: A novel platform to enhance CAR-T cell immunotherapy by combining RNAi technology to suppress genes that may impede CAR functionality.

LEARN MORE NOVEL TECHNOLOGY
NEW TECHNOLOGY NEW SOLUTION

Canine CAR-T Therapy Development: From early target discovery, CAR design and construction, cell culture, and transfection, to in vitro and in vivo function validation.

LEARN MORE SOLUTION
Receive our latest news and insights.