Get a real taste and understanding of the business and culture of one of the world's great research-based cellular and gene therapy discovery and development companies.
Creative Biolabs has a tradition of commitment. To achieve efficient execution and regulatory approval, we offer careful considerations of your program for the development of a cellular or gene therapy product – now and in the future.
To accelerate advanced breakthroughs of your projects, we offer broad range of platforms which enable our clients be free to tackle problems with cutting-edge technologies from different angles and in different methods.
Use the resources in our library to help you understand your options and make critical decisions for your study. We offer oncolytic virus, CAR-T, and dendritic cell related documents, as well as newsletter. If you don't find the answers you're looking for, contact us for additional assistance.
All products and services are For Research Use Only and CANNOT be used in the treatment or diagnosis of disease.
Creative Biolabs is committed to the development of tumor immunotherapy technology and cell therapy products. We have constructed a number of overexpression stable cell lines, which can be used for in vivo and in vitro pharmacodynamic experiments of CAR-T cells.
Specific Inquiry
Add to Cart
Specifications
Species
Hamster
Cell Type
CHO
Overexpressed Gene
CLDN18.2
Size
3x10^6 cell/ vial
Culture Condition
F12K+10%FBS
Growth Pattern
Adherent culture
Cell Purity
>95%
Cell Viability
>90%
Mycoplasma Testing
The cell line has been screened using the luciferase based mycoplasma detection kit to confirm the absence of mycoplasma species.
Shipping
Dry ice
Storage
-80°C for short-term storage, liquid nitrogen for long-term storage
Handling Notes
Cell Recovery:
1. Put on a protective mask and antifreeze gloves, remove the cells from the liquid nitrogen tank, and quickly put them in a 37°C water bath to thaw.
2. After the cells are thawed, transfer the cells to the cell chamber through the transfer chamber.
3. In the biological safety cabinet, take out a 15mL sterile centrifuge tube, and use a 1mL pipette to add 4mL medium to the 15mL centrifuge tube.
4. Use a 75% medical disinfectant alcohol cotton ball to carefully wipe the outer surface of the cell cryopreservation tube that has been thawed in a 37°C water bath for surface disinfection. In the biological safety cabinet, unscrew the cell cryopreservation tube, then use a 1mL pipette to aspirate the cell suspension in the tube, add it dropwise to the 15mL centrifuge tube containing 4mL medium prepared above, and screw the lid of the 15mL centrifuge tube. Tightly, slowly turn upside down 4 times to mix the cell suspension.
5. Place the centrifuge tube containing the cell suspension in the centrifuge and set the centrifugation parameters as follows: Centrifuge at 200xg at room temperature (~25°C) for 5 minutes.
6. After centrifugation, gently transfer the centrifuge tube to the biological safety cabinet. At this time, white cell clusters can be seen at the bottom of the cytocentrifuge tube. Use an electric aspirator to aspirate the medium supernatant (the cell cluster is relatively loose, be careful not to touch the cell cluster at the bottom).
7. Use a 1mL pipette to add 2mL of complete medium, gently pipette 5 times to resuspend the cell pellet, count, and inoculate.
8. Place the cells in an incubator for overnight culture.
Warnings
Avoid multiple freeze/thaw cycles
Research Use Only
Our recombinant Jurkat cell are for research use only, not for diagnostic or therapeutic use.
Quality Control
Cultures are screened for the presence of bacteries, yeast, fungi and mycoplasma (DNA amplification). Growth media are also certified based on U.S. Public Health Service Guidelines.
Tumorgenicity
Positive (In vitro/vivo transformation assay)
Oncogenicity
Positive (In vitro soft agarose assay and life-time studies )
Sterility Testing
Creative Biolabs provides sterility testing in accordance with USP and EP regulations. All of our sterility testing is performed in an isolator or clean room environments. The cell line has been screened using the membrane filtration testing methods to confirm the absence of aerobic, anaerobic and fungi microorganisms.
Identity Testing
Identity testing is required for newly established cell lines. Isoenzyme analysis is used to confirm the identity of the species of a cell line. Alternative methods for identity testing include DNA fingerprinting, STR analysis and karyology.
Virological Safety Testing
A broad range of viruses is susceptible to affecting human cell lines. We can provide in vivo/vitro virus saftey assays by utilizing various animal systems. These viruses include: adventitious viruses, bovine viruses, human and simian viruses, porcine viruses, retrovirus and rodent viruses.
Genetic Stability Testing
We perform cell genetic stability studies under ICH guidelines. We can provide guidance on the appropriate testing program upon your requirements.
Overexpressed Gene
CLDN18.2
Customer Reviews and Q&As
There are currently no customer reviews or questions for Chinese Hamster Ovary Stable Cell Line CHO-K1, CLDN18.2 Overexpressed (CAR-STC-ZP5). Click the button below to contact us or submit your feedback about this product.
For research use only. Not intended for any clinical use. No products from Creative Biolabs may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative Biolabs.
The latest newsletter to introduce the latest breaking information, our site updates, field and other scientific news, important events, and insights from industry leaders
CellRapeutics™ In Vivo Cell Engineering: One-stop in vivo T/B/NK cell and macrophage engineering services covering vectors construction to function verification.
Silence™ CAR-T Cell: A novel platform to enhance CAR-T cell immunotherapy by combining RNAi technology to suppress genes that may impede CAR functionality.
Canine CAR-T Therapy Development: From early target discovery, CAR design and construction, cell culture, and transfection, to in vitro and in vivo function validation.