Close

Human Liver Cancer Cell Line A549, Mesothlin/GFP Overexpressed (CAR-STC-ZP58)


All products and services are For Research Use Only and CANNOT be used in the treatment or diagnosis of disease.

Creative Biolabs is committed to the development of tumor immunotherapy technology and cell therapy products. We have constructed a number of overexpression stable cell lines, which can be used for in vivo and in vitro pharmacodynamic experiments of CAR-T cells.

Specific Inquiry

  • Size:
  Add to Cart

Specifications

  • Species
  • Human
  • Cell Type
  • Human liver cancer cells
  • Overexpressed Gene
  • Mesothlin-GFP
  • Size
  • 3x10^6 cell/ vial
  • Culture Condition
  • 1640+10%FBS
  • Growth Pattern
  • Adherent culture
  • Cell Purity
  • >95%
  • Cell Viability
  • >90%
  • Mycoplasma Testing
  • The cell line has been screened using the luciferase based mycoplasma detection kit to confirm the absence of mycoplasma species.
  • Shipping
  • Dry ice
  • Storage
  • -80°C for short-term storage, liquid nitrogen for long-term storage
  • Handling Notes
  • Cell Recovery:

    1. Put on a protective mask and antifreeze gloves, remove the cells from the liquid nitrogen tank, and quickly put them in a 37°C water bath to thaw.

    2. After the cells are thawed, transfer the cells to the cell chamber through the transfer chamber.

    3. In the biological safety cabinet, take out a 15mL sterile centrifuge tube, and use a 1mL pipette to add 4mL medium to the 15mL centrifuge tube.

    4. Use a 75% medical disinfectant alcohol cotton ball to carefully wipe the outer surface of the cell cryopreservation tube that has been thawed in a 37°C water bath for surface disinfection. In the biological safety cabinet, unscrew the cell cryopreservation tube, then use a 1mL pipette to aspirate the cell suspension in the tube, add it dropwise to the 15mL centrifuge tube containing 4mL medium prepared above, and screw the lid of the 15mL centrifuge tube. Tightly, slowly turn upside down 4 times to mix the cell suspension.

    5. Place the centrifuge tube containing the cell suspension in the centrifuge and set the centrifugation parameters as follows: Centrifuge at 200xg at room temperature (~25°C) for 5 minutes.

    6. After centrifugation, gently transfer the centrifuge tube to the biological safety cabinet. At this time, white cell clusters can be seen at the bottom of the cytocentrifuge tube. Use an electric aspirator to aspirate the medium supernatant (the cell cluster is relatively loose, be careful not to touch the cell cluster at the bottom).

    7. Use a 1mL pipette to add 2mL of complete medium, gently pipette 5 times to resuspend the cell pellet, count, and inoculate.

    8. Place the cells in an incubator for overnight culture.
  • Warnings
  • Avoid multiple freeze/thaw cycles
  • Research Use Only
  • Our recombinant Jurkat cell are for research use only, not for diagnostic or therapeutic use.
  • Quality Control
  • Cultures are screened for the presence of bacteries, yeast, fungi and mycoplasma (DNA amplification). Growth media are also certified based on U.S. Public Health Service Guidelines.
  • Tumorgenicity
  • Positive (In vitro/vivo transformation assay)
  • Oncogenicity
  • Positive (In vitro soft agarose assay and life-time studies )
  • Sterility Testing
  • Creative Biolabs provides sterility testing in accordance with USP and EP regulations. All of our sterility testing is performed in an isolator or clean room environments. The cell line has been screened using the membrane filtration testing methods to confirm the absence of aerobic, anaerobic and fungi microorganisms.
  • Identity Testing
  • Identity testing is required for newly established cell lines. Isoenzyme analysis is used to confirm the identity of the species of a cell line. Alternative methods for identity testing include DNA fingerprinting, STR analysis and karyology.
  • Virological Safety Testing
  • A broad range of viruses is susceptible to affecting human cell lines. We can provide in vivo/vitro virus saftey assays by utilizing various animal systems. These viruses include: adventitious viruses, bovine viruses, human and simian viruses, porcine viruses, retrovirus and rodent viruses.
  • Genetic Stability Testing
  • We perform cell genetic stability studies under ICH guidelines. We can provide guidance on the appropriate testing program upon your requirements.
  • Overexpressed Gene
  • Mesothlin-GFP

Customer Reviews and Q&As

There are currently no customer reviews or questions for Human Liver Cancer Stable Cell Line A549, Mesothlin/GFP Overexpressed (CAR-STC-ZP58). Click the button below to contact us or submit your feedback about this product.

For research use only. Not intended for any clinical use. No products from Creative Biolabs may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative Biolabs.

Related Products

Online Inquiry

For any technical issues or product/service related questions, please leave your information below. Our team will contact you soon.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Key Updates
Newsletter NEWSLETTER

The latest newsletter to introduce the latest breaking information, our site updates, field and other scientific news, important events, and insights from industry leaders

LEARN MORE NEWSLETTER
New Solution NEW SOLUTION

CellRapeutics™ In Vivo Cell Engineering: One-stop in vivo T/B/NK cell and macrophage engineering services covering vectors construction to function verification.

LEARN MORE SOLUTION
NOVEL SOLUTION NOVEL TECHNOLOGY

Silence™ CAR-T Cell: A novel platform to enhance CAR-T cell immunotherapy by combining RNAi technology to suppress genes that may impede CAR functionality.

LEARN MORE NOVEL TECHNOLOGY
NEW TECHNOLOGY NEW SOLUTION

Canine CAR-T Therapy Development: From early target discovery, CAR design and construction, cell culture, and transfection, to in vitro and in vivo function validation.

LEARN MORE SOLUTION
Receive our latest news and insights.